 Testing > Environmental Testing

¡¡

¡¡

 Environmental Testing

Climatic Test Chambers:

Chamber

Temperature Range

Humidity Capability

Temp Ramp Rate

Qty

Votsch VC 4018

-40¡ëC to 180¡ëC

20%-98%

2-3¡ëC/min

1

Votsch VC 4030

-40¡ëC to 180¡ëC

NA

2-3¡ëC/min

1

Votsch VC 7020

-70¡ëC to 180¡ëC

20%-98%

1¡ëC/min

1

Votsch VCS 7027-15

-80¡ëC to 180¡ëC

20%-98%

15¡ëC/min

2

Votsch VCV 7032-5*

-70¡ëC to 180¡ëC

20%-98%

5¡ëC/min

1

Votsch HT 7012 S2

-90¡ëC to 180¡ëC

NA

Duel zone thermal shock

1

Votsch VSC 450

Salt Spray

 

 

1

* This chamber can be used for combined temperature climate and vibration testing.

Vibration:

Gearing & Watson V350 shaker approx up to 90g from 5Hz to 2kHz 12.7mm p-p displacement (Can be used in combination with Votsch VCV 7032-5)

Two other smaller Gearing & Watson shakers.

Previous

 Australian Arrow Pty Ltd. © 2004 AAPL All Rights Reserved. Top of page